P1490: Tank Ventilation Valve 2 (N333), Short to Ground
Complete diagnostic information, symptoms, and potential causes
Manufacturer-Specific Variations
This code (P1490) may have different meanings or additional parameters depending on your vehicle's make, model, and year. Always verify with your vehicle's service manual or a qualified technician before attempting repairs.
Tank Ventilation Valve 2 (N333), Short to Ground
Description
Tank Ventilation Valve 2 (N333), Short to Ground
Common Symptoms
- Check Engine Light
- Secondary tank ventilation system inoperative
- Possible emission test failure
- Vent valve ground short warnings
Possible Causes
- Short to ground in tank ventilation valve 2 (N333) circuit
- Damaged wiring insulation in secondary vent system
- Internal valve short to ground
- Connector problems causing ground short
- Pinched wires in secondary vent system
Diagnosis Steps
- Test secondary tank ventilation valve circuit for short to ground
- Inspect wiring insulation and routing
- Check valve internal resistance for ground shorts
- Test circuit isolation from ground
- Check connector condition
Repair Solutions
- Repair or replace shorted wiring
- Replace faulty tank ventilation valve 2 (N333)
- Fix damaged connectors
- Address wiring routing issues
Prevention Tips
- Proper wiring installation and protection
- Protect vent system wiring from abrasion
- Regular secondary EVAP system electrical inspections
Working with ECU firmware? Remove DTCs directly from firmware files
Our free Firmware DTC Remover detects and removes hardcoded fault codes directly from ECU firmware files — no software needed. Supports BMW / MINI, VAG (VW, Audi, Porsche, Skoda, Seat, Cupra), PSA (Peugeot, Citroën, DS), Mercedes-Benz, Renault / Dacia / Samsung, Ford, Kia / Hyundai, Land Rover / Jaguar (EDC16, EDC17, MD1, MEVD17, MSV/MSD (7X/8X/9X), MS45, DCM3.7, DCM6.x, PCR2.1, DCM3.4, SID201, SID208, SID803/803A, SID807, CRD1.xx, CRD2.xx, CRD3.xx, SID3xx, SID202-SID206, SID209-SID211, DCM3.5, EMS22xx, EMS24xx (test), SIM210 (test), SIM28/29 (test), DCM3.2, SIM2K, SID20x, MED17). Free: 3 removals/day.