P1345: Ignition Coil Power Output Stage 3, Short to Ground
Complete diagnostic information, symptoms, and potential causes
Manufacturer-Specific Variations
This code (P1345) may have different meanings or additional parameters depending on your vehicle's make, model, and year. Always verify with your vehicle's service manual or a qualified technician before attempting repairs.
Ignition Coil Power Output Stage 3, Short to Ground
Description
Ignition coil power output stage 3 - short to ground.
Common Symptoms
- Check Engine Light
- Misfire in affected cylinders
- Rough idle
- Reduced engine performance
- Ignition system warnings
Possible Causes
- Short to ground in ignition coil power output stage 3 circuit
- Faulty ignition coil
- Damaged wiring harness
- Connector problems
- Ignition control module issues
Diagnosis Steps
- Test ignition output stage 3 circuit for short to ground
- Check ignition coil resistance
- Inspect wiring and connections
- Test ignition control module output
- Swap coils to test
Repair Solutions
- Repair short circuit in wiring
- Replace faulty ignition coil or output stage
- Fix connector or connection issues
- Address ignition control module problems
Prevention Tips
- Regular ignition system maintenance
- Protect electrical connections from moisture
- Address misfire codes promptly
Working with ECU firmware? Remove DTCs directly from firmware files
Our free Firmware DTC Remover detects and removes hardcoded fault codes directly from ECU firmware files — no software needed. Supports BMW / MINI, VAG (VW, Audi, Porsche, Skoda, Seat, Cupra), PSA (Peugeot, Citroën, DS), Mercedes-Benz, Renault / Dacia / Samsung, Ford, Kia / Hyundai, Land Rover / Jaguar (EDC16, EDC17, MD1, MEVD17, MSV/MSD (7X/8X/9X), MS45, DCM3.7, DCM6.x, PCR2.1, DCM3.4, SID201, SID208, SID803/803A, CRD1.xx, CRD2.xx, CRD3.xx, SID3xx, SID202-SID206, SID209-SID211, DCM3.5, EMS22xx, EMS24xx (test), SIM210 (test), SIM28/29 (test), DCM3.2, SIM2K, SID20x, MED17). Free: 3 removals/day.