P0135: Oxygen Sensor Bank 1 Sensor 1 Heating Circuit Malfunction
Complete diagnostic information, symptoms, and potential causes
Manufacturer-Specific Variations
This code (P0135) may have different meanings or additional parameters depending on your vehicle's make, model, and year. Always verify with your vehicle's service manual or a qualified technician before attempting repairs.
Oxygen Sensor Bank 1 Sensor 1 Heating Circuit Malfunction
Description
Oxygen (Lambda) Sensor Bank-1 Sensor-1, Heating Circuit: Malfunction
Common Symptoms
- Check Engine Light
- Oxygen sensor heater circuit malfunction
- Extended sensor warm-up time
- Delayed closed loop fuel operation
- Increased emissions during cold start
Possible Causes
- Failed O2 sensor heater element
- Open or short in heater circuit
- Heater circuit fuse or relay issues
- ECU heater control fault
- Sensor connector heater pin problems
Diagnosis Steps
- Test O2 sensor heater circuit resistance
- Check for opens or shorts in heater wiring
- Verify heater circuit power and ground
- Test heater control from ECU
- Monitor sensor warm-up time
Repair Solutions
- Replace oxygen sensor with failed heater
- Repair heater circuit wiring issues
- Fix power/ground problems to heater
- Address ECU heater control if faulty
- Reset emission system after repair
Prevention Tips
- Regular heater circuit checks
- Address heater issues before complete sensor failure
- Monitor cold start emission performance
Working with ECU firmware? Remove DTCs directly from firmware files
Our free Firmware DTC Remover detects and removes hardcoded fault codes directly from ECU firmware files — no software needed. Supports BMW / MINI, VAG (VW, Audi, Porsche, Skoda, Seat, Cupra), PSA (Peugeot, Citroën, DS), Mercedes-Benz, Renault / Dacia / Samsung, Ford, Kia / Hyundai, Land Rover / Jaguar (EDC16, EDC17, MD1, MEVD17, MSV/MSD (7X/8X/9X), MS45, DCM3.7, DCM6.x, PCR2.1, DCM3.4, SID201, SID208, SID803/803A, CRD1.xx, CRD2.xx, CRD3.xx, SID3xx, SID202-SID206, SID209-SID211, DCM3.5, EMS22xx, EMS24xx (test), SIM210 (test), SIM28/29 (test), DCM3.2, SIM2K, SID20x, MED17). Free: 3 removals/day.